SATO CL608VA Instrukcja Operatora Strona 144

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 143
Start/Stop Label
Command Structure Start Command: <ESC>A
Stop Command: <ESC>Z
Example: See above
Placement: <ESC>A must precede data
<ESC>Z must follow data
Default: None
Command Function For all print jobs, the Start command must precede the data, and the
Stop command must follow. The print job will not run properly if these
are not in place.
Input to Printer
<ESC>A
<ESC>H0001<ESC>V0100<ESC>WB1SATO
<ESC>H0130<ESC>V0200<ESC>B103150*CL408*
<ESC>H0170<ESC>V0360<ESC>L0202<ESC>S*CL408*
<ESC>Q1<ESC>Z
Printer Output There is not output for these commands they are not accompanied by
other label printing commands. However, these commands must
precede and follow each print job sent to the printer.
Section 4. Programming Reference
Page 4-749001035 Rev. ESATOCL SeriesPrinters
Przeglądanie stron 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 255 256

Komentarze do niniejszej Instrukcji

Brak uwag